Data & Methodology — Spotsylvania County

Full contaminant data, sample history, and sourcing for Spotsylvania County. For readers who want to go beyond the summary.

Contaminant Data — All Analytes

196 well testing events on record, covering 20 analytes. Data spans 1967 to 2025.

Contaminant Samples Years Detection Rate Distribution LowModHigh vs. Limit vs. VA Avg
Arsenic 2 1999–2007 0%
Chloride 3 1999–2024 100%
1% of limit ↓ 95% below
Fluoride 3 1999–2024 33%
4% of limit ~ typical
HFPO-DA (GenX) municipal 10 2023–2024 0%
Iron 2 1999–2007 0%
Lead 2 1999–2007 50%
5% of limit ↑ 93% above
Manganese 2 1999–2007 50%
5% of limit ↓ 96% below
Nitrate 2 2007–2024 100%
3% of limit ↓ 54% below
Nitrite 2 2007–2024 50%
0% of limit ↓ 83% below
PFHxS municipal 10 2023–2024 0%
PFNA municipal 10 2023–2024 0%
PFOA municipal 10 2023–2024 0%
PFOS municipal 10 2023–2024 0%
Radon 2 1999–2007 100%
18% of limit ↓ 78% below
Sulfate 3 1999–2024 100%
1% of limit ↓ 95% below
Uranium 2 1999–2007 100%
7% of limit ↑ 1223% above
Hardness 3 1999–2024 100%
↓ 64% below
PFBS municipal 10 2023–2024 0%
pH 2 1999–2007 100%
~ typical
Sodium 3 1999–2024 100%
↓ 62% below

Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across VA.

Data Coverage & Gaps

Limited data (<15 samples) — interpret with caution

  • Arsenic 2 samples
  • Chloride 3 samples
  • Fluoride 3 samples
  • Iron 2 samples
  • Lead 2 samples
  • Manganese 2 samples
  • Nitrate 2 samples
  • Nitrite 2 samples
  • Radon 2 samples
  • Sulfate 3 samples
  • Uranium 2 samples
  • Hardness 3 samples
  • pH 2 samples
  • Sodium 3 samples

No private-well PFAS data for Spotsylvania County

We have no private well sampling data for PFAS compounds (PFOA, PFOS, PFNA, and related chemicals) in Spotsylvania County. PFAS testing for private wells requires a dedicated lab panel (~$300–$500). If you are near a military base, airport, or industrial site, consider testing proactively. Learn more about PFAS →

Public vs. Private Water in Spotsylvania County

38 Active public water systems
108,100 Residents on public water

Public water systems in Spotsylvania County are regulated by the EPA and must test and report contaminant levels. Private well owners are responsible for their own testing — there is no routine monitoring of private wells by any government agency.

CDC Health Outcome Correlations

Where contaminants detected in Spotsylvania County have established associations with specific health outcomes, we cross-reference CDC PLACES county-level prevalence data. This is a contextual signal, not a causal claim.

Contaminant Associated Condition Spotsylvania County Prevalence VA Average Source Year
Arsenic Cancer prevalence 6.7% 6.7% 2020
Arsenic Kidney disease rate 2.7% 3.1% 2020

Source: CDC PLACES county-level estimates. Raw data: Download Spotsylvania County CDC PLACES data →

Data Sources

This report aggregates data from the following public databases:

Methodology

Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.

Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.

State comparison uses the median of county median values across all counties in VA with at least one sample for that analyte.

Last updated: 2026-07-15

Full methodology →