Contaminant Data — All Analytes

312 well testing events on record, covering 19 analytes. Data spans 1964 to 2022.

Contaminant Samples Years Detection Rate Distribution LowModHigh vs. Limit vs. TX Avg
Iron 150 1960–2018 85%
67% of limit
Manganese 80 1964–2018 82%
48% of limit
PFOS municipal 30 2023–2025 7%
155% of limit
Sulfate 62 1969–1994 100%
11% of limit
Nitrate 58 1969–2004 95%
4% of limit
Lead 61 1993–2018 10%
29% of limit
Arsenic 65 1989–2018 3%
20% of limit
Chloride 62 1969–1994 100%
10% of limit
Fluoride 268 1959–2018 91%
3% of limit
HFPO-DA (GenX) municipal 30 2023–2025 0%
Nitrite 5 1994 40%
1% of limit
PFHxS municipal 30 2023–2025 13%
34% of limit
PFNA municipal 30 2023–2025 0%
PFOA municipal 30 2023–2025 0%
Uranium 30 1994–2018 0%
Sodium 62 1969–1994 100%
pH 62 1969–1994 100%
PFBS municipal 30 2023–2025 0%
Hardness 62 1969–1994 100%

Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across TX.

Data Coverage & Gaps

Well-sampled analytes (15+ samples)

  • Iron 150 samples
  • Manganese 80 samples
  • Sulfate 62 samples
  • Nitrate 58 samples
  • Lead 61 samples
  • Arsenic 65 samples
  • Chloride 62 samples
  • Fluoride 268 samples
  • Uranium 30 samples
  • Sodium 62 samples
  • pH 62 samples
  • Hardness 62 samples

Limited data (<15 samples) — interpret with caution

  • Nitrite 5 samples

No private-well PFAS data for Van Zandt County

We have no private well sampling data for PFAS compounds (PFOA, PFOS, PFNA, and related chemicals) in Van Zandt County. PFAS has been detected in local public water systems (UCMR 5 data) — indicated by the "municipal" badge in the table above — but this does not directly indicate private well contamination. PFAS testing for private wells requires a dedicated lab panel (~$300–$500). If you are near a military base, airport, or industrial site, consider testing proactively. Learn more about PFAS →

Public vs. Private Water in Van Zandt County

23 Active public water systems
55,045 Residents on public water

Public water systems in Van Zandt County are regulated by the EPA and must test and report contaminant levels. Private well owners are responsible for their own testing — there is no routine monitoring of private wells by any government agency.

CDC Health Outcome Correlations

Where contaminants detected in Van Zandt County have established associations with specific health outcomes, we cross-reference CDC PLACES county-level prevalence data. This is a contextual signal, not a causal claim.

Contaminant Associated Condition Van Zandt County Prevalence TX Average Source Year
Nitrate Cancer prevalence 5.9% 6.1% 2020
Lead Heart disease rate 6.6% 7.4% 2020

Source: CDC PLACES county-level estimates. Raw data: Download Van Zandt County CDC PLACES data →

Data Sources

This report aggregates data from the following public databases:

Methodology

Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.

Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.

State comparison uses the median of county median values across all counties in TX with at least one sample for that analyte.

Last updated: 2026-07-15

Full methodology →