Data & Methodology — Terrell County

Full contaminant data, sample history, and sourcing for Terrell County. For readers who want to go beyond the summary.

Contaminant Data — All Analytes

176 well testing events on record, covering 16 analytes. Data spans 2000 to 2025.

Contaminant Samples Years Detection Rate Distribution LowModHigh vs. Limit vs. TX Avg
Iron 131 1955–2021 40%
14% of limit ↓ 91% below
Lead 123 1986–2021 15%
12% of limit ↓ 29% below
Manganese 125 1955–2021 38%
10% of limit ↓ 84% below
Fluoride 175 1950–2021 98%
18% of limit ↓ 27% below
Arsenic 123 1986–2021 6%
10% of limit ↓ 74% below
Chloride 2 2017 100%
7% of limit ↓ 80% below
Nitrate 43 1993–2017 98%
18% of limit ~ typical
Nitrite 2 2017 0%
— —
Radon 2 2017 100%
60% of limit ↑ 67% above
Sulfate 2 2017 100%
8% of limit ↓ 72% below
Uranium 29 2011–2021 93%
10% of limit ↓ 37% below
E. coli 2 2017 0%
— —
Hardness 2 2017 100%
— ~ typical
pH 2 2017 100%
— ~ typical
Sodium 2 2017 100%
— ↓ 88% below
Total Coliform 2 2017 0%
— —

Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across TX.

Compare your result with Terrell County

Of the 123 arsenic tests on record for Terrell County (1986–2021), 94% found none.

Of the 175 fluoride tests on record for Terrell County (1950–2021), 2% found none, and half were below 700 µg/L.

Of the 131 iron tests on record for Terrell County (1955–2021), 60% found none.

Of the 123 lead tests on record for Terrell County (1986–2021), 85% found none.

Of the 125 manganese tests on record for Terrell County (1955–2021), 62% found none.

Of the 43 nitrate tests on record for Terrell County (1993–2017), 2% found none, and half were below 1.75 mg/L.

Of the 29 uranium tests on record for Terrell County (2011–2021), 7% found none, and half were below 2.9 µg/L.

Have a number from your lab? Enter it to see where it falls. Nothing is sent anywhere.

Want the full picture for your well? Check all your results.

Data Coverage & Gaps

Well-sampled analytes (15+ samples)

  • Iron 131 samples
  • Lead 123 samples
  • Manganese 125 samples
  • Fluoride 175 samples
  • Arsenic 123 samples
  • Nitrate 43 samples
  • Uranium 29 samples

Limited data (<15 samples) — interpret with caution

  • Chloride 2 samples
  • Nitrite 2 samples
  • Radon 2 samples
  • Sulfate 2 samples
  • E. coli 2 samples
  • Hardness 2 samples
  • pH 2 samples
  • Sodium 2 samples
  • Total Coliform 2 samples

No private-well PFAS data for Terrell County

We have no private well sampling data for PFAS compounds (PFOA, PFOS, PFNA, and related chemicals) in Terrell County. PFAS testing for private wells requires a dedicated lab panel (~$300–$500). If you are near a military base, airport, or industrial site, consider testing proactively. Learn more about PFAS →

Public vs. Private Water in Terrell County

2 Active public water systems
827 Residents on public water
13% Households on private wells

Public water systems in Terrell County are regulated by the EPA and must test and report contaminant levels. Private well owners are responsible for their own testing — there is no routine monitoring of private wells by any government agency.

CDC Health Outcome Correlations

Where contaminants detected in Terrell County have established associations with specific health outcomes, we cross-reference CDC PLACES county-level prevalence data. This is a contextual signal, not a causal claim.

Contaminant Associated Condition Terrell County Prevalence TX Average Source Year
Lead Heart disease rate 6.4% 7.4% 2020

Source: CDC PLACES county-level estimates. Raw data: Download Terrell County CDC PLACES data →

Data Sources

This report aggregates data from the following public databases:

Methodology

Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.

Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.

State comparison uses the median of county median values across all counties in TX with at least one sample for that analyte.

Last updated: 2026-08-04

Full methodology →