259 well testing events on record, covering 20 analytes. Data spans 2001 to 2003.

Contaminant Samples Years Detection Rate Distribution LowModHigh vs. Limit vs. TX Avg
Fluoride 255 1939–2021 100%
66% of limit ↑ 175% above
Arsenic 106 1991–2021 69%
55% of limit ↑ 44% above
Iron 132 1945–2021 38%
22% of limit ↓ 85% below
Manganese 128 1955–2021 45%
6% of limit ↓ 91% below
Chloride 2 2001–2003 100%
7% of limit ↓ 80% below
HFPO-DA (GenX) municipal 4 2024 0%
— —
Lead 106 1991–2021 6%
10% of limit ↓ 42% below
Nitrate 19 1991–2003 100%
12% of limit ↓ 48% below
Nitrite 2 2001–2003 0%
— —
PFHxS municipal 4 2024 0%
— —
PFNA municipal 4 2024 0%
— —
PFOA municipal 4 2024 0%
— —
PFOS municipal 4 2024 0%
— —
Radon 1 2001 100%
12% of limit ↓ 67% below
Sulfate 2 2001–2003 100%
11% of limit ↓ 62% below
Uranium 38 2001–2021 87%
26% of limit ↑ 67% above
Hardness 2 2001–2003 100%
— ~ typical
PFBS municipal 4 2024 0%
— —
pH 2 2001–2003 100%
— ~ typical
Sodium 2 2001–2003 100%
— ↓ 60% below

Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across TX.

Compare your result with Swisher County

Of the 106 arsenic tests on record for Swisher County (1991–2021), 31% found none, and half were below 4.29 µg/L.

Of the 255 fluoride tests on record for Swisher County (1939–2021), 0% found none, and half were below 2.63 mg/L.

Of the 132 iron tests on record for Swisher County (1945–2021), 62% found none.

Of the 106 lead tests on record for Swisher County (1991–2021), 94% found none.

Of the 128 manganese tests on record for Swisher County (1955–2021), 55% found none.

Of the 38 uranium tests on record for Swisher County (2001–2021), 13% found none, and half were below 7.09 µg/L.

Have a number from your lab? Enter it to see where it falls. Nothing is sent anywhere.

Want the full picture for your well? Check all your results.

Data Coverage & Gaps

Well-sampled analytes (15+ samples)

  • Fluoride 255 samples
  • Arsenic 106 samples
  • Iron 132 samples
  • Manganese 128 samples
  • Lead 106 samples
  • Nitrate 19 samples
  • Uranium 38 samples

Limited data (<15 samples) — interpret with caution

  • Chloride 2 samples
  • Nitrite 2 samples
  • Radon 1 sample
  • Sulfate 2 samples
  • Hardness 2 samples
  • pH 2 samples
  • Sodium 2 samples

No private-well PFAS data for Swisher County

We have no private well sampling data for PFAS compounds (PFOA, PFOS, PFNA, and related chemicals) in Swisher County. PFAS testing for private wells requires a dedicated lab panel (~$300–$500). If you are near a military base, airport, or industrial site, consider testing proactively. Learn more about PFAS →

Public vs. Private Water in Swisher County

4 Active public water systems
6,201 Residents on public water
15% Households on private wells

Public water systems in Swisher County are regulated by the EPA and must test and report contaminant levels. Private well owners are responsible for their own testing — there is no routine monitoring of private wells by any government agency.

CDC Health Outcome Correlations

Where contaminants detected in Swisher County have established associations with specific health outcomes, we cross-reference CDC PLACES county-level prevalence data. This is a contextual signal, not a causal claim.

Contaminant Associated Condition Swisher County Prevalence TX Average Source Year
Arsenic Cancer prevalence 5.3% 6.1% 2020
Arsenic Kidney disease rate 3.7% 3.3% 2020

Source: CDC PLACES county-level estimates. Raw data: Download Swisher County CDC PLACES data →

Data Sources

This report aggregates data from the following public databases:

Methodology

Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.

Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.

State comparison uses the median of county median values across all counties in TX with at least one sample for that analyte.

Last updated: 2026-08-04

Full methodology →