Data & Methodology — Real County

Full contaminant data, sample history, and sourcing for Real County. For readers who want to go beyond the summary.

Contaminant Data — All Analytes

92 well testing events on record, covering 14 analytes. Data spans 1990 to 2010.

Contaminant Samples Years Detection Rate Distribution LowModHigh vs. Limit vs. TX Avg
Lead 37 1990–2021 16%
20% of limit ~ typical
Fluoride 92 1956–2021 90%
4% of limit ↓ 85% below
Arsenic 37 1990–2021 3%
10% of limit ↓ 74% below
Chloride 2 1990 100%
48% of limit ↑ 34% above
Iron 39 1956–2021 33%
24% of limit ↓ 84% below
Manganese 35 1993–2021 17%
3% of limit ↓ 95% below
Nitrate 10 1990–1999 80%
18% of limit ~ typical
Nitrite 2 1990 50%
1% of limit ~ typical
Radon 1 1990 100%
11% of limit ↓ 69% below
Sulfate 2 1990 100%
66% of limit ↑ 131% above
Uranium 6 2007–2021 17%
3% of limit ↓ 81% below
Hardness 2 1990 100%
— ↓ 26% below
pH 2 1990 100%
— ~ typical
Sodium 2 1990 100%
— ↑ 95% above

Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across TX.

Compare your result with Real County

Of the 37 arsenic tests on record for Real County (1990–2021), 97% found none.

Of the 92 fluoride tests on record for Real County (1956–2021), 10% found none, and half were below 130 µg/L.

Of the 39 iron tests on record for Real County (1956–2021), 67% found none.

Of the 37 lead tests on record for Real County (1990–2021), 84% found none.

Of the 35 manganese tests on record for Real County (1993–2021), 83% found none.

Have a number from your lab? Enter it to see where it falls. Nothing is sent anywhere.

Want the full picture for your well? Check all your results.

Data Coverage & Gaps

Well-sampled analytes (15+ samples)

  • Lead 37 samples
  • Fluoride 92 samples
  • Arsenic 37 samples
  • Iron 39 samples
  • Manganese 35 samples

Limited data (<15 samples) — interpret with caution

  • Chloride 2 samples
  • Nitrate 10 samples
  • Nitrite 2 samples
  • Radon 1 sample
  • Sulfate 2 samples
  • Uranium 6 samples
  • Hardness 2 samples
  • pH 2 samples
  • Sodium 2 samples

No private-well PFAS data for Real County

We have no private well sampling data for PFAS compounds (PFOA, PFOS, PFNA, and related chemicals) in Real County. PFAS testing for private wells requires a dedicated lab panel (~$300–$500). If you are near a military base, airport, or industrial site, consider testing proactively. Learn more about PFAS →

Public vs. Private Water in Real County

12 Active public water systems
6,717 Residents on public water
47% Households on private wells

Public water systems in Real County are regulated by the EPA and must test and report contaminant levels. Private well owners are responsible for their own testing — there is no routine monitoring of private wells by any government agency.

CDC Health Outcome Correlations

Where contaminants detected in Real County have established associations with specific health outcomes, we cross-reference CDC PLACES county-level prevalence data. This is a contextual signal, not a causal claim.

Contaminant Associated Condition Real County Prevalence TX Average Source Year
Lead Heart disease rate 12.4% 7.4% 2020

Source: CDC PLACES county-level estimates. Raw data: Download Real County CDC PLACES data →

Data Sources

This report aggregates data from the following public databases:

Methodology

Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.

Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.

State comparison uses the median of county median values across all counties in TX with at least one sample for that analyte.

Last updated: 2026-08-04

Full methodology →