Data & Methodology — Panola County

Full contaminant data, sample history, and sourcing for Panola County. For readers who want to go beyond the summary.

Contaminant Data — All Analytes

244 well testing events on record, covering 20 analytes. Data spans 1956 to 2020.

Contaminant Samples Years Detection Rate Distribution LowModHigh vs. Limit vs. TX Avg
Iron 146 1943–2018 81%
34% of limit
Chloride 10 1979–2015 100%
57% of limit
Manganese 97 1946–2018 74%
39% of limit
Lead 62 1980–2018 11%
4% of limit
Fluoride 227 1943–2018 93%
6% of limit
Arsenic 63 1980–2018 17%
30% of limit
HFPO-DA (GenX) municipal 4 2024 0%
Nitrate 19 1989–2015 32%
0% of limit
Nitrite 9 2004–2015 22%
0% of limit
PFHxS municipal 4 2024 0%
PFNA municipal 4 2024 0%
PFOA municipal 4 2024 0%
PFOS municipal 4 2024 0%
Radon 5 2004–2015 100%
8% of limit
Sulfate 10 1979–2015 90%
2% of limit
Uranium 29 2004–2018 3%
0% of limit
Hardness 10 1979–2015 100%
PFBS municipal 4 2024 0%
pH 10 1979–2015 100%
Sodium 9 2004–2015 100%

Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across TX.

Data Coverage & Gaps

Well-sampled analytes (15+ samples)

  • Iron 146 samples
  • Manganese 97 samples
  • Lead 62 samples
  • Fluoride 227 samples
  • Arsenic 63 samples
  • Nitrate 19 samples
  • Uranium 29 samples

Limited data (<15 samples) — interpret with caution

  • Chloride 10 samples
  • Nitrite 9 samples
  • Radon 5 samples
  • Sulfate 10 samples
  • Hardness 10 samples
  • pH 10 samples
  • Sodium 9 samples

No private-well PFAS data for Panola County

We have no private well sampling data for PFAS compounds (PFOA, PFOS, PFNA, and related chemicals) in Panola County. PFAS testing for private wells requires a dedicated lab panel (~$300–$500). If you are near a military base, airport, or industrial site, consider testing proactively. Learn more about PFAS →

Public vs. Private Water in Panola County

22 Active public water systems
24,505 Residents on public water

Public water systems in Panola County are regulated by the EPA and must test and report contaminant levels. Private well owners are responsible for their own testing — there is no routine monitoring of private wells by any government agency.

CDC Health Outcome Correlations

Where contaminants detected in Panola County have established associations with specific health outcomes, we cross-reference CDC PLACES county-level prevalence data. This is a contextual signal, not a causal claim.

Contaminant Associated Condition Panola County Prevalence TX Average Source Year
Lead Heart disease rate 6.7% 7.4% 2020

Source: CDC PLACES county-level estimates. Raw data: Download Panola County CDC PLACES data →

Data Sources

This report aggregates data from the following public databases:

Methodology

Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.

Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.

State comparison uses the median of county median values across all counties in TX with at least one sample for that analyte.

Last updated: 2026-07-15

Full methodology →