Data & Methodology — Palo Pinto County

Full contaminant data, sample history, and sourcing for Palo Pinto County. For readers who want to go beyond the summary.

Contaminant Data — All Analytes

74 well testing events on record, covering 13 analytes. Data spans 1959 to 2023.

Contaminant Samples Years Detection Rate Distribution LowModHigh vs. Limit vs. TX Avg
Manganese 10 1960–2019 50%
46% of limit
Iron 22 1931–2019 64%
52% of limit
Fluoride 60 1956–2019 98%
12% of limit
Arsenic 7 1988–2019 14%
69% of limit
HFPO-DA (GenX) municipal 8 2024–2025 0%
Lead 7 1988–2019 0%
Nitrate 10 1976–1995 70%
2% of limit
PFHxS municipal 8 2024–2025 0%
PFNA municipal 8 2024–2025 0%
PFOA municipal 8 2024–2025 0%
PFOS municipal 8 2024–2025 0%
Uranium 2 2016–2019 50%
9% of limit
PFBS municipal 8 2024–2025 0%

Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across TX.

Data Coverage & Gaps

Well-sampled analytes (15+ samples)

  • Iron 22 samples
  • Fluoride 60 samples

Limited data (<15 samples) — interpret with caution

  • Manganese 10 samples
  • Arsenic 7 samples
  • Lead 7 samples
  • Nitrate 10 samples
  • Uranium 2 samples

No private-well PFAS data for Palo Pinto County

We have no private well sampling data for PFAS compounds (PFOA, PFOS, PFNA, and related chemicals) in Palo Pinto County. PFAS testing for private wells requires a dedicated lab panel (~$300–$500). If you are near a military base, airport, or industrial site, consider testing proactively. Learn more about PFAS →

Public vs. Private Water in Palo Pinto County

17 Active public water systems
42,483 Residents on public water

Public water systems in Palo Pinto County are regulated by the EPA and must test and report contaminant levels. Private well owners are responsible for their own testing — there is no routine monitoring of private wells by any government agency.

Data Sources

This report aggregates data from the following public databases:

Methodology

Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.

Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.

State comparison uses the median of county median values across all counties in TX with at least one sample for that analyte.

Last updated: 2026-07-15

Full methodology →