Data & Methodology — Llano County

Full contaminant data, sample history, and sourcing for Llano County. For readers who want to go beyond the summary.

Contaminant Data — All Analytes

172 well testing events on record, covering 13 analytes. Data spans 1967 to 2025.

Contaminant Samples Years Detection Rate Distribution LowModHigh vs. Limit vs. TX Avg
Nitrate 13 1974–2005 100%
63% of limit ↑ 181% above
Iron 56 1972–2017 54%
62% of limit ↓ 60% below
Arsenic 24 1988–2017 4%
24% of limit ↓ 37% below
Fluoride 158 1959–2017 99%
20% of limit ~ typical
HFPO-DA (GenX) municipal 15 2023–2025 0%
— —
Lead 18 1988–2017 6%
15% of limit ~ typical
Manganese 24 1988–2017 33%
3% of limit ↓ 95% below
PFHxS municipal 15 2023–2025 0%
— —
PFNA municipal 15 2023–2025 0%
— —
PFOA municipal 15 2023–2025 0%
— —
PFOS municipal 15 2023–2025 0%
— —
Uranium 2 2008–2017 50%
51% of limit ↑ 226% above
PFBS municipal 15 2023–2025 0%
— —

Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across TX.

Compare your result with Llano County

Of the 24 arsenic tests on record for Llano County (1988–2017), 96% found none.

Of the 158 fluoride tests on record for Llano County (1959–2017), 1% found none, and half were below 800 µg/L.

Of the 56 iron tests on record for Llano County (1972–2017), 46% found none, and half were below 22.8 µg/L.

Of the 24 manganese tests on record for Llano County (1988–2017), 67% found none.

Have a number from your lab? Enter it to see where it falls. Nothing is sent anywhere.

Want the full picture for your well? Check all your results.

Data Coverage & Gaps

Well-sampled analytes (15+ samples)

  • Iron 56 samples
  • Arsenic 24 samples
  • Fluoride 158 samples
  • Lead 18 samples
  • Manganese 24 samples

Limited data (<15 samples) — interpret with caution

  • Nitrate 13 samples
  • Uranium 2 samples

No private-well PFAS data for Llano County

We have no private well sampling data for PFAS compounds (PFOA, PFOS, PFNA, and related chemicals) in Llano County. PFAS testing for private wells requires a dedicated lab panel (~$300–$500). If you are near a military base, airport, or industrial site, consider testing proactively. Learn more about PFAS →

Public vs. Private Water in Llano County

27 Active public water systems
39,555 Residents on public water
9% Households on private wells

Public water systems in Llano County are regulated by the EPA and must test and report contaminant levels. Private well owners are responsible for their own testing — there is no routine monitoring of private wells by any government agency.

CDC Health Outcome Correlations

Where contaminants detected in Llano County have established associations with specific health outcomes, we cross-reference CDC PLACES county-level prevalence data. This is a contextual signal, not a causal claim.

Contaminant Associated Condition Llano County Prevalence TX Average Source Year
Nitrate Cancer prevalence 6.0% 6.1% 2020

Source: CDC PLACES county-level estimates. Raw data: Download Llano County CDC PLACES data →

Data Sources

This report aggregates data from the following public databases:

Methodology

Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.

Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.

State comparison uses the median of county median values across all counties in TX with at least one sample for that analyte.

Last updated: 2026-08-04

Full methodology →