Data & Methodology — Howard County

Full contaminant data, sample history, and sourcing for Howard County. For readers who want to go beyond the summary.

Contaminant Data — All Analytes

244 well testing events on record, covering 22 analytes. Data spans 1965 to 2025.

Contaminant Samples Years Detection Rate Distribution LowModHigh vs. Limit vs. TX Avg
Chloride 30 1987–2017 100%
440% of limit ↑ 1130% above
Sulfate 10 1987–2017 100%
306% of limit ↑ 973% above
Nitrate 24 1989–2017 96%
101% of limit ↑ 354% above
Arsenic 96 1983–2019 76%
130% of limit ↑ 241% above
Fluoride 207 1961–2019 100%
38% of limit ↑ 57% above
PFHxS municipal 7 2023–2025 71%
54% of limit ↑ 23% above
PFOS municipal 7 2023–2025 14%
110% of limit ~ typical
Iron 90 1985–2019 53%
22% of limit ↓ 86% below
Uranium 13 2001–2019 100%
34% of limit ↑ 117% above
Manganese 70 1965–2019 49%
10% of limit ↓ 85% below
HFPO-DA (GenX) municipal 7 2023–2025 0%
— —
Lead 67 1989–2019 4%
2% of limit ↓ 87% below
Nitrite 2 2001–2017 0%
— —
PFNA municipal 7 2023–2025 0%
— —
PFOA municipal 7 2023–2025 0%
— —
Radon 2 2001–2017 100%
26% of limit ↓ 28% below
Total Coliform 1 2017 100%
— ~ typical
Sodium 10 1987–2017 100%
— ↑ 400% above
pH 10 1987–2017 100%
— ~ typical
PFBS municipal 7 2023–2025 43%
— ↑ 36% above
E. coli 1 2017 0%
— —
Hardness 10 1987–2017 100%
— ↑ 302% above

Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across TX.

Compare your result with Howard County

Of the 96 arsenic tests on record for Howard County (1983–2019), 24% found none, and half were below 8.98 µg/L.

Of the 30 chloride tests on record for Howard County (1987–2017), 0% found none, and half were below 1100 mg/L.

Of the 207 fluoride tests on record for Howard County (1961–2019), 0% found none, and half were below 1.5 mg/L.

Of the 90 iron tests on record for Howard County (1985–2019), 47% found none, and half were below 11.1 µg/L.

Of the 67 lead tests on record for Howard County (1989–2019), 96% found none.

Of the 70 manganese tests on record for Howard County (1965–2019), 51% found none.

Of the 24 nitrate tests on record for Howard County (1989–2017), 4% found none, and half were below 9.7 mg/L.

Have a number from your lab? Enter it to see where it falls. Nothing is sent anywhere.

Want the full picture for your well? Check all your results.

Data Coverage & Gaps

Well-sampled analytes (15+ samples)

  • Chloride 30 samples
  • Nitrate 24 samples
  • Arsenic 96 samples
  • Fluoride 207 samples
  • Iron 90 samples
  • Manganese 70 samples
  • Lead 67 samples

Limited data (<15 samples) — interpret with caution

  • Sulfate 10 samples
  • Uranium 13 samples
  • Nitrite 2 samples
  • Radon 2 samples
  • Total Coliform 1 sample
  • Sodium 10 samples
  • pH 10 samples
  • E. coli 1 sample
  • Hardness 10 samples

No private-well PFAS data for Howard County

We have no private well sampling data for PFAS compounds (PFOA, PFOS, PFNA, and related chemicals) in Howard County. PFAS has been detected in local public water systems (UCMR 5 data) — indicated by the "municipal" badge in the table above — but this does not directly indicate private well contamination. PFAS testing for private wells requires a dedicated lab panel (~$300–$500). If you are near a military base, airport, or industrial site, consider testing proactively. Learn more about PFAS →

Public vs. Private Water in Howard County

9 Active public water systems
32,403 Residents on public water
15% Households on private wells

Public water systems in Howard County are regulated by the EPA and must test and report contaminant levels. Private well owners are responsible for their own testing — there is no routine monitoring of private wells by any government agency.

CDC Health Outcome Correlations

Where contaminants detected in Howard County have established associations with specific health outcomes, we cross-reference CDC PLACES county-level prevalence data. This is a contextual signal, not a causal claim.

Contaminant Associated Condition Howard County Prevalence TX Average Source Year
Arsenic Cancer prevalence 5.4% 6.1% 2020
Arsenic Kidney disease rate 3.1% 3.3% 2020

Source: CDC PLACES county-level estimates. Raw data: Download Howard County CDC PLACES data →

Data Sources

This report aggregates data from the following public databases:

Methodology

Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.

Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.

State comparison uses the median of county median values across all counties in TX with at least one sample for that analyte.

Last updated: 2026-08-04

Full methodology →