Data & Methodology — Hartley County

Full contaminant data, sample history, and sourcing for Hartley County. For readers who want to go beyond the summary.

Contaminant Data — All Analytes

308 well testing events on record, covering 16 analytes. Data spans 1968 to 2021.

Contaminant Samples Years Detection Rate Distribution LowModHigh vs. Limit vs. TX Avg
Iron 166 1961–2021 27%
18% of limit ↓ 89% below
Arsenic 157 1987–2021 67%
27% of limit ↓ 29% below
Manganese 162 1979–2021 25%
5% of limit ↓ 93% below
Chloride 17 1999–2021 100%
4% of limit ↓ 89% below
Fluoride 304 1948–2021 100%
30% of limit ↑ 26% above
Lead 154 1987–2021 6%
2% of limit ↓ 89% below
Nitrate 59 1979–2021 98%
21% of limit ~ typical
Nitrite 17 1999–2021 0%
— —
Radon 4 1999 100%
8% of limit ↓ 77% below
Sulfate 17 1999–2021 100%
12% of limit ↓ 59% below
Uranium 31 1999–2021 100%
24% of limit ↑ 57% above
E. coli 1 2010–2021 50%
— ~ typical
Hardness 17 1999–2021 100%
— ~ typical
pH 17 1999–2021 100%
— ~ typical
Sodium 17 1999–2021 100%
— ↓ 78% below
Total Coliform 1 2021 0%
— —

Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across TX.

Compare your result with Hartley County

Of the 157 arsenic tests on record for Hartley County (1987–2021), 33% found none, and half were below 2 µg/L.

Of the 304 fluoride tests on record for Hartley County (1948–2021), 0% found none, and half were below 1.2 mg/L.

Of the 166 iron tests on record for Hartley County (1961–2021), 73% found none.

Of the 154 lead tests on record for Hartley County (1987–2021), 94% found none.

Of the 162 manganese tests on record for Hartley County (1979–2021), 75% found none.

Of the 59 nitrate tests on record for Hartley County (1979–2021), 2% found none, and half were below 2.07 mg/L.

Of the 31 uranium tests on record for Hartley County (1999–2021), 0% found none, and half were below 7.29 µg/L.

Have a number from your lab? Enter it to see where it falls. Nothing is sent anywhere.

Want the full picture for your well? Check all your results.

Data Coverage & Gaps

Well-sampled analytes (15+ samples)

  • Iron 166 samples
  • Arsenic 157 samples
  • Manganese 162 samples
  • Chloride 17 samples
  • Fluoride 304 samples
  • Lead 154 samples
  • Nitrate 59 samples
  • Nitrite 17 samples
  • Sulfate 17 samples
  • Uranium 31 samples
  • Hardness 17 samples
  • pH 17 samples
  • Sodium 17 samples

Limited data (<15 samples) — interpret with caution

  • Radon 4 samples
  • E. coli 1 sample
  • Total Coliform 1 sample

No private-well PFAS data for Hartley County

We have no private well sampling data for PFAS compounds (PFOA, PFOS, PFNA, and related chemicals) in Hartley County. PFAS testing for private wells requires a dedicated lab panel (~$300–$500). If you are near a military base, airport, or industrial site, consider testing proactively. Learn more about PFAS →

Public vs. Private Water in Hartley County

3 Active public water systems
730 Residents on public water
26% Households on private wells

Public water systems in Hartley County are regulated by the EPA and must test and report contaminant levels. Private well owners are responsible for their own testing — there is no routine monitoring of private wells by any government agency.

CDC Health Outcome Correlations

Where contaminants detected in Hartley County have established associations with specific health outcomes, we cross-reference CDC PLACES county-level prevalence data. This is a contextual signal, not a causal claim.

Contaminant Associated Condition Hartley County Prevalence TX Average Source Year
Arsenic Cancer prevalence 5.6% 6.1% 2020
Arsenic Kidney disease rate 2.6% 3.3% 2020

Source: CDC PLACES county-level estimates. Raw data: Download Hartley County CDC PLACES data →

Data Sources

This report aggregates data from the following public databases:

Methodology

Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.

Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.

State comparison uses the median of county median values across all counties in TX with at least one sample for that analyte.

Last updated: 2026-08-04