Contaminant Data — All Analytes

328 well testing events on record, covering 22 analytes. Data spans 1964 to 2016.

Contaminant Samples Years Detection Rate Distribution LowModHigh vs. Limit vs. TX Avg
Arsenic 152 1977–2021 75%
50% of limit ↑ 31% above
Sulfate 10 2001–2016 100%
16% of limit ↓ 42% below
Chloride 10 2001–2016 100%
25% of limit ↓ 29% below
Manganese 163 1942–2021 25%
10% of limit ↓ 84% below
Nitrate 33 1990–2016 97%
12% of limit ↓ 48% below
Iron 168 1942–2021 18%
21% of limit ↓ 87% below
Fluoride 323 1942–2021 100%
65% of limit ↑ 172% above
HFPO-DA (GenX) municipal 12 2023–2024 0%
— —
Lead 149 1977–2021 13%
9% of limit ↓ 49% below
Nitrite 10 2001–2016 20%
22% of limit ↑ 2055% above
PFHxS municipal 12 2023–2024 0%
— —
PFNA municipal 12 2023–2024 0%
— —
PFOA municipal 12 2023–2024 0%
— —
PFOS municipal 12 2023–2024 0%
— —
Radon 7 2001–2016 100%
10% of limit ↓ 72% below
Uranium 53 2001–2021 100%
28% of limit ↑ 83% above
E. coli 1 2016 0%
— —
Hardness 10 2001–2016 100%
— ~ typical
PFBS municipal 12 2023–2024 0%
— —
pH 10 2001–2016 100%
— ~ typical
Sodium 10 2001–2016 100%
— ↓ 44% below
Total Coliform 1 2016 0%
— —

Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across TX.

Compare your result with Hale County

Of the 152 arsenic tests on record for Hale County (1977–2021), 25% found none, and half were below 4.17 µg/L.

Of the 323 fluoride tests on record for Hale County (1942–2021), 0% found none, and half were below 2.6 mg/L.

Of the 168 iron tests on record for Hale County (1942–2021), 82% found none.

Of the 149 lead tests on record for Hale County (1977–2021), 87% found none.

Of the 163 manganese tests on record for Hale County (1942–2021), 75% found none.

Of the 33 nitrate tests on record for Hale County (1990–2016), 3% found none, and half were below 1.15 mg/L.

Of the 53 uranium tests on record for Hale County (2001–2021), 0% found none, and half were below 8.5 µg/L.

Have a number from your lab? Enter it to see where it falls. Nothing is sent anywhere.

Want the full picture for your well? Check all your results.

Data Coverage & Gaps

Well-sampled analytes (15+ samples)

  • Arsenic 152 samples
  • Manganese 163 samples
  • Nitrate 33 samples
  • Iron 168 samples
  • Fluoride 323 samples
  • Lead 149 samples
  • Uranium 53 samples

Limited data (<15 samples) — interpret with caution

  • Sulfate 10 samples
  • Chloride 10 samples
  • Nitrite 10 samples
  • Radon 7 samples
  • E. coli 1 sample
  • Hardness 10 samples
  • pH 10 samples
  • Sodium 10 samples
  • Total Coliform 1 sample

No private-well PFAS data for Hale County

We have no private well sampling data for PFAS compounds (PFOA, PFOS, PFNA, and related chemicals) in Hale County. PFAS testing for private wells requires a dedicated lab panel (~$300–$500). If you are near a military base, airport, or industrial site, consider testing proactively. Learn more about PFAS →

Public vs. Private Water in Hale County

20 Active public water systems
30,494 Residents on public water
6% Households on private wells

Public water systems in Hale County are regulated by the EPA and must test and report contaminant levels. Private well owners are responsible for their own testing — there is no routine monitoring of private wells by any government agency.

CDC Health Outcome Correlations

Where contaminants detected in Hale County have established associations with specific health outcomes, we cross-reference CDC PLACES county-level prevalence data. This is a contextual signal, not a causal claim.

Contaminant Associated Condition Hale County Prevalence TX Average Source Year
Arsenic Cancer prevalence 5.4% 6.1% 2020
Arsenic Kidney disease rate 3.4% 3.3% 2020

Source: CDC PLACES county-level estimates. Raw data: Download Hale County CDC PLACES data →

Data Sources

This report aggregates data from the following public databases:

Methodology

Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.

Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.

State comparison uses the median of county median values across all counties in TX with at least one sample for that analyte.

Last updated: 2026-08-04

Full methodology →