Data & Methodology — Colorado County

Full contaminant data, sample history, and sourcing for Colorado County. For readers who want to go beyond the summary.

Contaminant Data — All Analytes

400 well testing events on record, covering 13 analytes. Data spans 1967 to 2024.

Contaminant Samples Years Detection Rate Distribution LowModHigh vs. Limit vs. TX Avg
Iron 285 1942–2020 67%
65% of limit ↓ 58% below
Arsenic 133 1977–2020 26%
25% of limit ↓ 35% below
Manganese 232 1942–2020 33%
17% of limit ↓ 74% below
Fluoride 366 1942–2020 93%
8% of limit ↓ 69% below
HFPO-DA (GenX) municipal 8 2023–2025 0%
— —
Lead 122 1977–2020 0%
— —
Nitrate 26 1974–2006 92%
6% of limit ↓ 74% below
PFHxS municipal 8 2023–2025 0%
— —
PFNA municipal 8 2023–2025 0%
— —
PFOA municipal 8 2023–2025 0%
— —
PFOS municipal 8 2023–2025 0%
— —
Uranium 52 2006–2020 40%
19% of limit ↑ 25% above
PFBS municipal 8 2023–2025 0%
— —

Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across TX.

Compare your result with Colorado County

Of the 133 arsenic tests on record for Colorado County (1977–2020), 74% found none.

Of the 366 fluoride tests on record for Colorado County (1942–2020), 7% found none, and half were below 300 µg/L.

Of the 285 iron tests on record for Colorado County (1942–2020), 33% found none, and half were below 70 µg/L.

Of the 122 lead tests on record for Colorado County (1977–2020), 100% found none.

Of the 232 manganese tests on record for Colorado County (1942–2020), 67% found none.

Of the 26 nitrate tests on record for Colorado County (1974–2006), 8% found none, and half were below 450 µg/L.

Of the 52 uranium tests on record for Colorado County (2006–2020), 60% found none.

Have a number from your lab? Enter it to see where it falls. Nothing is sent anywhere.

Want the full picture for your well? Check all your results.

Data Coverage & Gaps

Well-sampled analytes (15+ samples)

  • Iron 285 samples
  • Arsenic 133 samples
  • Manganese 232 samples
  • Fluoride 366 samples
  • Lead 122 samples
  • Nitrate 26 samples
  • Uranium 52 samples

No private-well PFAS data for Colorado County

We have no private well sampling data for PFAS compounds (PFOA, PFOS, PFNA, and related chemicals) in Colorado County. PFAS testing for private wells requires a dedicated lab panel (~$300–$500). If you are near a military base, airport, or industrial site, consider testing proactively. Learn more about PFAS →

Public vs. Private Water in Colorado County

46 Active public water systems
18,181 Residents on public water
32% Households on private wells

Public water systems in Colorado County are regulated by the EPA and must test and report contaminant levels. Private well owners are responsible for their own testing — there is no routine monitoring of private wells by any government agency.

CDC Health Outcome Correlations

Where contaminants detected in Colorado County have established associations with specific health outcomes, we cross-reference CDC PLACES county-level prevalence data. This is a contextual signal, not a causal claim.

Contaminant Associated Condition Colorado County Prevalence TX Average Source Year
Arsenic Cancer prevalence 7.7% 6.1% 2020
Arsenic Kidney disease rate 3.0% 3.3% 2020

Source: CDC PLACES county-level estimates. Raw data: Download Colorado County CDC PLACES data →

Data Sources

This report aggregates data from the following public databases:

Methodology

Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.

Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.

State comparison uses the median of county median values across all counties in TX with at least one sample for that analyte.

Last updated: 2026-08-04