Data & Methodology — Caldwell County

Full contaminant data, sample history, and sourcing for Caldwell County. For readers who want to go beyond the summary.

Contaminant Data — All Analytes

555 well testing events on record, covering 20 analytes. Data spans 1942 to 2016.

Contaminant Samples Years Detection Rate Distribution LowModHigh vs. Limit vs. TX Avg
Manganese 62 1938–2020 60%
334% of limit ↑ 419% above
Iron 257 1938–2020 91%
67% of limit ↓ 57% below
Nitrate 246 1938–2015 97%
14% of limit ↓ 37% below
Chloride 302 1938–2015 100%
54% of limit ↑ 52% above
Sulfate 292 1938–2015 100%
28% of limit ~ typical
Fluoride 353 1938–2020 97%
8% of limit ↓ 69% below
Arsenic 27 1992–2020 15%
1% of limit ↓ 98% below
HFPO-DA (GenX) municipal 15 2024–2025 0%
— —
Lead 27 1992–2020 15%
6% of limit ↓ 65% below
Nitrite 7 2008–2015 0%
— —
PFHxS municipal 15 2024–2025 0%
— —
PFNA municipal 15 2024–2025 0%
— —
PFOA municipal 15 2024–2025 0%
— —
PFOS municipal 15 2024–2025 0%
— —
Radon 3 2008 100%
4% of limit ↓ 90% below
Uranium 11 2008–2020 27%
0% of limit ↓ 99% below
Sodium 169 1938–2015 100%
— ~ typical
pH 158 1938–2015 100%
— ~ typical
PFBS municipal 15 2024–2025 0%
— —
Hardness 169 1938–2015 100%
— ~ typical

Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across TX.

Compare your result with Caldwell County

Of the 27 arsenic tests on record for Caldwell County (1992–2020), 85% found none.

Of the 302 chloride tests on record for Caldwell County (1938–2015), 0% found none, and half were below 136 mg/L.

Of the 353 fluoride tests on record for Caldwell County (1938–2020), 3% found none, and half were below 300 µg/L.

Of the 257 iron tests on record for Caldwell County (1938–2020), 9% found none, and half were below 150 µg/L.

Of the 27 lead tests on record for Caldwell County (1992–2020), 85% found none.

Of the 62 manganese tests on record for Caldwell County (1938–2020), 40% found none, and half were below 18.1 µg/L.

Of the 246 nitrate tests on record for Caldwell County (1938–2015), 3% found none, and half were below 1.2 mg/L.

Of the 292 sulfate tests on record for Caldwell County (1938–2015), 0% found none, and half were below 70 mg/L.

Have a number from your lab? Enter it to see where it falls. Nothing is sent anywhere.

Want the full picture for your well? Check all your results.

Data Coverage & Gaps

Well-sampled analytes (15+ samples)

  • Manganese 62 samples
  • Iron 257 samples
  • Nitrate 246 samples
  • Chloride 302 samples
  • Sulfate 292 samples
  • Fluoride 353 samples
  • Arsenic 27 samples
  • Lead 27 samples
  • Sodium 169 samples
  • pH 158 samples
  • Hardness 169 samples

Limited data (<15 samples) — interpret with caution

  • Nitrite 7 samples
  • Radon 3 samples
  • Uranium 11 samples

No private-well PFAS data for Caldwell County

We have no private well sampling data for PFAS compounds (PFOA, PFOS, PFNA, and related chemicals) in Caldwell County. PFAS testing for private wells requires a dedicated lab panel (~$300–$500). If you are near a military base, airport, or industrial site, consider testing proactively. Learn more about PFAS →

CDC Health Outcome Correlations

Where contaminants detected in Caldwell County have established associations with specific health outcomes, we cross-reference CDC PLACES county-level prevalence data. This is a contextual signal, not a causal claim.

Contaminant Associated Condition Caldwell County Prevalence TX Average Source Year
Nitrate Cancer prevalence 5.7% 6.1% 2020

Source: CDC PLACES county-level estimates. Raw data: Download Caldwell County CDC PLACES data →

Data Sources

This report aggregates data from the following public databases:

Methodology

Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.

Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.

State comparison uses the median of county median values across all counties in TX with at least one sample for that analyte.

Last updated: 2026-08-04

Full methodology →