Data & Methodology — Bell County

Full contaminant data, sample history, and sourcing for Bell County. For readers who want to go beyond the summary.

Contaminant Data — All Analytes

657 well testing events on record, covering 22 analytes. Data spans 1961 to 2024.

Contaminant Samples Years Detection Rate Distribution LowModHigh vs. Limit vs. TX Avg
Iron 393 1939–2022 83%
53% of limit ↓ 65% below
Sulfate 43 2012–2022 100%
8% of limit ↓ 72% below
Fluoride 592 1938–2022 100%
55% of limit ↑ 130% above
Chloride 42 2012–2022 100%
6% of limit ↓ 84% below
Manganese 321 1938–2022 25%
12% of limit ↓ 81% below
PFOS municipal 108 2023–2025 3%
148% of limit ~ typical
Lead 110 1976–2022 9%
1% of limit ↓ 94% below
PFHxS municipal 108 2023–2025 28%
37% of limit ~ typical
Arsenic 108 1979–2022 37%
4% of limit ↓ 90% below
HFPO-DA (GenX) municipal 108 2023–2025 0%
— —
Nitrate 70 1970–2022 83%
37% of limit ↑ 67% above
Nitrite 43 2012–2022 16%
1% of limit ↓ 42% below
PFNA municipal 108 2023–2025 0%
— —
PFOA municipal 108 2023–2025 0%
— —
Radon 1 2017 100%
15% of limit ↓ 58% below
Uranium 67 2007–2022 52%
3% of limit ↓ 82% below
Total Coliform 1 2017 0%
— —
Sodium 42 2012–2022 100%
— ↓ 89% below
pH 44 2012–2022 100%
— ~ typical
PFBS municipal 107 2023–2025 23%
— ~ typical
Hardness 43 2012–2022 100%
— ↑ 21% above
E. coli 1 2017 0%
— —

Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across TX.

Compare your result with Bell County

Of the 108 arsenic tests on record for Bell County (1979–2022), 63% found none.

Of the 42 chloride tests on record for Bell County (2012–2022), 0% found none, and half were below 14.2 mg/L.

Of the 592 fluoride tests on record for Bell County (1938–2022), 0% found none, and half were below 2.2 mg/L.

Of the 393 iron tests on record for Bell County (1939–2022), 17% found none, and half were below 120 µg/L.

Of the 110 lead tests on record for Bell County (1976–2022), 91% found none.

Of the 321 manganese tests on record for Bell County (1938–2022), 75% found none.

Of the 70 nitrate tests on record for Bell County (1970–2022), 17% found none, and half were below 705 µg/L.

Of the 43 sulfate tests on record for Bell County (2012–2022), 0% found none, and half were below 20.1 mg/L.

Of the 67 uranium tests on record for Bell County (2007–2022), 48% found none, and half were below 0.432 µg/L.

Have a number from your lab? Enter it to see where it falls. Nothing is sent anywhere.

Want the full picture for your well? Check all your results.

Data Coverage & Gaps

Well-sampled analytes (15+ samples)

  • Iron 393 samples
  • Sulfate 43 samples
  • Fluoride 592 samples
  • Chloride 42 samples
  • Manganese 321 samples
  • Lead 110 samples
  • Arsenic 108 samples
  • Nitrate 70 samples
  • Nitrite 43 samples
  • Uranium 67 samples
  • Sodium 42 samples
  • pH 44 samples
  • Hardness 43 samples

Limited data (<15 samples) — interpret with caution

  • Radon 1 sample
  • Total Coliform 1 sample
  • E. coli 1 sample

No private-well PFAS data for Bell County

We have no private well sampling data for PFAS compounds (PFOA, PFOS, PFNA, and related chemicals) in Bell County. PFAS testing for private wells requires a dedicated lab panel (~$300–$500). If you are near a military base, airport, or industrial site, consider testing proactively. Learn more about PFAS →

CDC Health Outcome Correlations

Where contaminants detected in Bell County have established associations with specific health outcomes, we cross-reference CDC PLACES county-level prevalence data. This is a contextual signal, not a causal claim.

Contaminant Associated Condition Bell County Prevalence TX Average Source Year
Lead Heart disease rate 6.2% 7.4% 2020
PFOS Cancer prevalence 5.1% 6.1% 2020

Source: CDC PLACES county-level estimates. Raw data: Download Bell County CDC PLACES data →

Data Sources

This report aggregates data from the following public databases:

Methodology

Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.

Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.

State comparison uses the median of county median values across all counties in TX with at least one sample for that analyte.

Last updated: 2026-08-04

Full methodology →