Data & Methodology — Brown County

Full contaminant data, sample history, and sourcing for Brown County. For readers who want to go beyond the summary.

Contaminant Data — All Analytes

32 well testing events on record, covering 22 analytes. Data spans 1965 to 2024.

Contaminant Samples Years Detection Rate Distribution LowModHigh vs. Limit vs. OH Avg
Manganese 19 1997–2019 100%
78% of limit ↓ 56% below
PFOA municipal 20 2023–2024 5%
118% of limit ~ typical
Arsenic 19 1997–2019 84%
0% of limit ↓ 100% below
Chloride 19 1997–2019 100%
10% of limit ↓ 36% below
Fluoride 19 1997–2019 89%
7% of limit ↓ 34% below
HFPO-DA (GenX) municipal 20 2023–2024 0%
— —
Iron 19 1997–2019 89%
0% of limit ↓ 100% below
Lead 19 1997–2019 84%
0% of limit ↓ 100% below
Nitrate 1 2019 0%
— —
Nitrite 1 2019 0%
— —
PFHxS municipal 20 2023–2024 0%
— —
PFNA municipal 20 2023–2024 0%
— —
PFOS municipal 20 2023–2024 0%
— —
Radon 1 2019 100%
90% of limit ↑ 307% above
Sulfate 3 2012–2019 100%
25% of limit ↓ 43% below
Uranium 1 2019 100%
2% of limit ↓ 32% below
Total Coliform 1 2019 0%
— —
Sodium 19 1997–2019 100%
— ↓ 44% below
pH 15 1997–2019 100%
— ~ typical
PFBS municipal 20 2023–2024 0%
— —
Hardness 19 1997–2019 100%
— ↓ 53% below
E. coli 1 2019 0%
— —

Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across OH.

Data Coverage & Gaps

Well-sampled analytes (15+ samples)

  • Manganese 19 samples
  • Arsenic 19 samples
  • Chloride 19 samples
  • Fluoride 19 samples
  • Iron 19 samples
  • Lead 19 samples
  • Sodium 19 samples
  • pH 15 samples
  • Hardness 19 samples

Limited data (<15 samples) — interpret with caution

  • Nitrate 1 sample
  • Nitrite 1 sample
  • Radon 1 sample
  • Sulfate 3 samples
  • Uranium 1 sample
  • Total Coliform 1 sample
  • E. coli 1 sample

No private-well PFAS data for Brown County

We have no private well sampling data for PFAS compounds (PFOA, PFOS, PFNA, and related chemicals) in Brown County. PFAS testing for private wells requires a dedicated lab panel (~$300–$500). If you are near a military base, airport, or industrial site, consider testing proactively. Learn more about PFAS →

CDC Health Outcome Correlations

Where contaminants detected in Brown County have established associations with specific health outcomes, we cross-reference CDC PLACES county-level prevalence data. This is a contextual signal, not a causal claim.

Contaminant Associated Condition Brown County Prevalence OH Average Source Year
PFOA Cancer prevalence 6.1% 6.8% 2020

Source: CDC PLACES county-level estimates. Raw data: Download Brown County CDC PLACES data →

Data Sources

This report aggregates data from the following public databases:

Methodology

Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.

Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.

State comparison uses the median of county median values across all counties in OH with at least one sample for that analyte.

Last updated: 2026-08-04

Full methodology →