Data & Methodology — Wayne County

Full contaminant data, sample history, and sourcing for Wayne County. For readers who want to go beyond the summary.

Contaminant Data — All Analytes

35 well testing events on record, covering 22 analytes. Data spans 1937 to 2024.

Contaminant Samples Years Detection Rate Distribution LowModHigh vs. Limit vs. GA Avg
Lead 16 1976–2013 12%
1000% of limit ↑ 65288% above
Radon 5 1993–2005 100%
5% of limit ↓ 71% below
Uranium 8 1993–2013 38%
0% of limit ↓ 84% below
Arsenic 16 1976–2013 12%
5% of limit ~ typical
Chloride 28 1960–2013 100%
3% of limit ↑ 64% above
Fluoride 20 1960–2013 95%
14% of limit ↑ 190% above
HFPO-DA (GenX) municipal 8 2024 0%
— —
Iron 16 1976–2013 94%
33% of limit ~ typical
Manganese 16 1976–2013 56%
3% of limit ↓ 95% below
Nitrate 21 1960–2013 67%
0% of limit ↓ 100% below
Nitrite 16 1976–2013 12%
1% of limit ↓ 40% below
PFHxS municipal 8 2024 0%
— —
PFNA municipal 8 2024 0%
— —
PFOA municipal 8 2024 0%
— —
PFOS municipal 8 2024 0%
— —
Radon 5 1993–2005 100%
5% of limit ↓ 71% below
Sulfate 20 1960–2013 100%
11% of limit ↑ 448% above
Uranium 8 1993–2013 38%
0% of limit ↓ 84% below
Hardness 20 1960–2013 100%
— ↑ 74% above
PFBS municipal 8 2024 0%
— —
pH 22 1960–2013 100%
— ~ typical
Sodium 20 1960–2013 100%
— ↑ 131% above

Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across GA.

Compare your result with Wayne County

Of the 28 chloride tests on record for Wayne County (1960–2013), 0% found none, and half were below 7.65 mg/L.

Of the 20 fluoride tests on record for Wayne County (1960–2013), 5% found none, and half were below 575 µg/L.

Of the 21 nitrate tests on record for Wayne County (1960–2013), 33% found none.

Of the 20 sulfate tests on record for Wayne County (1960–2013), 0% found none, and half were below 27.9 mg/L.

Have a number from your lab? Enter it to see where it falls. Nothing is sent anywhere.

Want the full picture for your well? Check all your results.

Data Coverage & Gaps

Well-sampled analytes (15+ samples)

  • Lead 16 samples
  • Arsenic 16 samples
  • Chloride 28 samples
  • Fluoride 20 samples
  • Iron 16 samples
  • Manganese 16 samples
  • Nitrate 21 samples
  • Nitrite 16 samples
  • Sulfate 20 samples
  • Hardness 20 samples
  • pH 22 samples
  • Sodium 20 samples

Limited data (<15 samples) — interpret with caution

  • Radon 5 samples
  • Uranium 8 samples
  • Radon 5 samples
  • Uranium 8 samples

No private-well PFAS data for Wayne County

We have no private well sampling data for PFAS compounds (PFOA, PFOS, PFNA, and related chemicals) in Wayne County. PFAS testing for private wells requires a dedicated lab panel (~$300–$500). If you are near a military base, airport, or industrial site, consider testing proactively. Learn more about PFAS →

Public vs. Private Water in Wayne County

29 Active public water systems
15,538 Residents on public water
53% Households on private wells

Public water systems in Wayne County are regulated by the EPA and must test and report contaminant levels. Private well owners are responsible for their own testing — there is no routine monitoring of private wells by any government agency.

CDC Health Outcome Correlations

Where contaminants detected in Wayne County have established associations with specific health outcomes, we cross-reference CDC PLACES county-level prevalence data. This is a contextual signal, not a causal claim.

Contaminant Associated Condition Wayne County Prevalence GA Average Source Year
Lead Heart disease rate 8.4% 7.7% 2020

Source: CDC PLACES county-level estimates. Raw data: Download Wayne County CDC PLACES data →

Data Sources

This report aggregates data from the following public databases:

Methodology

Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.

Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.

State comparison uses the median of county median values across all counties in GA with at least one sample for that analyte.

Last updated: 2026-08-04

Full methodology →