Data & Methodology — Dooly County

Full contaminant data, sample history, and sourcing for Dooly County. For readers who want to go beyond the summary.

Contaminant Data — All Analytes

30 well testing events on record, covering 11 analytes. Data spans 1963 to 2022.

Contaminant Samples Years Detection Rate Distribution LowModHigh vs. Limit vs. GA Avg
Fluoride 16 1963–1981 75%
2% of limit ↓ 50% below
Nitrite 2 1981 0%
Sulfate 17 1963–1981 100%
1% of limit ↓ 47% below
PFOS municipal 16 2023–2024 0%
PFHxS municipal 16 2023–2024 0%
Nitrate 15 1963–1981 100%
3% of limit ↓ 47% below
Manganese 1 1977 0%
Sodium 16 1963–1981 100%
↓ 75% below
pH 23 1963–1981 100%
~ typical
Hardness 24 1963–1981 100%
↑ 56% above
PFBS municipal 16 2023–2024 0%

Distribution shows the share of samples in each concentration band relative to the EPA Maximum Contaminant Level (MCL): Low = below half the MCL, Moderate = between half and the MCL, High = above the MCL. Analytes without an MCL (e.g. sodium, pH) show — in the limit columns. State average is based on county median values across GA.

Data Coverage & Gaps

Well-sampled analytes (15+ samples)

  • Fluoride 16 samples
  • Sulfate 17 samples
  • Nitrate 15 samples
  • Sodium 16 samples
  • pH 23 samples
  • Hardness 24 samples

Limited data (<15 samples) — interpret with caution

  • Nitrite 2 samples
  • Manganese 1 sample

No private-well PFAS data for Dooly County

We have no private well sampling data for PFAS compounds (PFOA, PFOS, PFNA, and related chemicals) in Dooly County. PFAS testing for private wells requires a dedicated lab panel (~$300–$500). If you are near a military base, airport, or industrial site, consider testing proactively. Learn more about PFAS →

Public vs. Private Water in Dooly County

7 Active public water systems
9,350 Residents on public water

Public water systems in Dooly County are regulated by the EPA and must test and report contaminant levels. Private well owners are responsible for their own testing — there is no routine monitoring of private wells by any government agency.

Data Sources

This report aggregates data from the following public databases:

Methodology

Raw records are downloaded from the Water Quality Portal and normalized to µg/L (ppb). Records are deduplicated by sample ID and date, and certified outliers are excluded. Analyte names are mapped to EPA canonical forms. Detection rates, distribution bands, and MCL comparisons are computed from the normalized dataset.

Distribution bands use the EPA Maximum Contaminant Level as the threshold: concentrations below 50% of the MCL are classed as Low, between 50% and 100% as Moderate, and above 100% as High. For analytes without an MCL (sodium, hardness, pH), distribution is not computed.

State comparison uses the median of county median values across all counties in GA with at least one sample for that analyte.

Last updated: 2026-08-03